The Open Electrical & Electronic Engineering Journal
2011, 5 : 24-28Published online 2011 August 16. DOI: 10.2174/1874129001105010024
Publisher ID: TOEEJ-5-24
Analysis of Structural Stress in 8x8 InSb Array Detector
ABSTRACT
Based on viscoplastic Anand’s model, structural stress of 8x8 InSb array detector dependent on indium bump sizes is systemically researched by finite element method. For the detector with underfill, simulation results show that as the diameters of indium bump decrease from 36µm to 20µm in step of 2µm, the maximum stress existing in InSb chip first reduces sharply, then increases flatly, and reaches minimum with indium bump diameter 32µm. When the height of indium bump increases from 9µm to 21µm in step of 6µm, the maximal stress in InSb chip first reduces sharply from 800MPa to 500MPa, then almost remains constant. This phenomenon is contrary to the detector without underfill, where the stress is smaller with lower indium height. In the whole device, the maximal Von Mises stress appears in the InSb chip with 10µm, and the minimal Von Mises stress appears in the indium bump array with 16MPa, almost 1/10 of that in underfill encapsulate, where the stress is180MPa. It is noticed that when the Von Mises stress reaches minimum with some selected indium bump dimensions, its stress distribution is uniform and concentrated at all contacting areas, this is favorable to reduce the crack happening in InSb chip, and improve the yield.